Gas Manifold Assemblies
Manifolds
Each manifold part number consists of four sections. The first section denotes a Gas Manifold Assembly (GMA). The second section denotes the type of manifold and its configuration (only for duplex manifolds) otherwise do not use configuration number. The third section denotes the CGA number or type of gas, and the last section denotes the number of outlets or cylinders.
The simple duplex manifold is an economical system with a two cylinder capacity, one per side. The unit is furnished with two header valves and two pigtails with check valves or two outlet adaptors with check valves and two regular pigtails, 1/2" NPT tee, a union and a mounting bracket. Manifolds for Acetylene gas will include pigtails with dry type flashback arrestors.
The simple duplex manifold is an economical system with a two cylinder capacity, one per side. The unit is furnished with two header valves and two pigtails with check valves or two outlet adaptors with check valves and two regular pigtails, 1/2" NPT tee, a union and a mounting bracket. Manifolds for Acetylene gas will include pigtails with dry type flashback arrestors.
Item # |
Item Name |
CGA Standard |
Application |
Material |
Working Pressure |
Part |
Quantity |
---|---|---|---|---|---|---|---|
GMF-3011 /Asset/GMF-3011.gif | N/A Brass Manifold Pipe Elbow | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Elbow | |
GMF-3012 /Asset/GMF-3012.gif | N/A Brass Manifold Pipe Elbow | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Elbow | |
GMF-3013 /Asset/GMF-3013.gif | N/A Brass Manifold Pipe Elbow | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Elbow | |
GMF-3021 /Asset/GMF-3021.gif | N/A Brass Manifold Pipe Tee | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Tee | |
GMF-3022 /Asset/GMF-3022.gif | N/A Brass Manifold Pipe Tee | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Tee | |
GMF-3023 /Asset/GMF-3023.gif | N/A Brass Manifold Pipe Tee | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Tee | |
GMF-3033 /Asset/GMF-3033.gif | N/A Brass Manifold Pipe Tee | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Tee | |
GMF-3034 /Asset/GMF-3034.gif | N/A Brass Manifold Pipe Tee | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Tee | |
GMF-3041 /Asset/GMF-3041.gif | N/A Brass Manifold Pipe Cross | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Cross | |
GMF-3042 /Asset/GMF-3042.gif | N/A Brass Manifold Pipe Cross | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Cross | |
GMF-3043 /Asset/GMF-3043.gif | N/A Brass Manifold Pipe Cross | CGA Standard N/A | Application N/A Oxygen | Material N/A CDA 360 Brass | Working Pressure N/A 3000 psi | Part N/A Pipe Cross | |
GMA-DM1-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Standard Configuration | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM1-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Standard Configuration, w/ Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM2-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Crossover Configuration | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM2-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Crossover Configuration, w/ Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM3-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, "L" Shaped Configuration | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM3-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, "L" Shaped Configuration, w/ Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM4-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, "U" Shaped Configuration | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM4-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, "U" Shaped Configuration, w/ Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM5-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Staggered Configuration | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-DM5-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Duplex (Manual) Gas Manifold Assembly, Staggered Configuration, w/ Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-SD-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Simple Duplex (Manual) Gas Manifold Assembly | CGA Standard N/A 300 | Application N/A Ethyl Chloride | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-SD-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Simple Duplex (Manual) Gas Manifold Assembly, Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-SM-300 /Asset/Gas-Manifold-Assemblies.JPG | N/A Simplex (Manual) Gas Manifold Assembly | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold | |
GMA-SM-300CV /Asset/Gas-Manifold-Assemblies.JPG | N/A Simplex (Manual) Gas Manifold Assembly, Outlet Adaptors w/ Check Valves | CGA Standard N/A 300 | Application N/A Commercial Acetylene | Material N/A | Working Pressure N/A | Part N/A Manifold |